56B2 Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions. Both outstanding and inexpensive, it has the best cost performance that can satisfy any customer.
n The Ventilator adopts microcomputer control with high-definition 5.7” LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
n The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
n Reliable pneumatic transmission system.
n Economic and proper configuration of technologies, optional as required by the Customer.
n Modularized design and upgrading. Upgrading is available as required by the Customer.
Part of Anesthesia Machine
■Main body High-strength engineering plastic rack, light,
beautiful and corrosion resistant
■Scope of application adult, child
■Gas source O2: 0.28~0.6MPa N2O: 0.28~0.6MPa
■Flow meter O2: 0.05~10L/min N2O: 0.05~10L/min
■O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
■Flow rate of rapid oxygen supply 25~75L/min
■Low oxygen pressure alarm There will be sound alarm when the oxygen pressure < 0.2MPa
■Vaporizer it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
■Low oxygen pressure alarm There will be sound alarm when the oxygen pressure<0.2Mpa
■Respiratory circuit working mode: all-close, semi-close, semi-open
APL≤12.5kpa
■Respiratory bellows bellows for adults, bellows for children
tidal volume range:0~1500 ml
Part of Ventilator
■Display mode High-definition 5.7” LCD screen display
■Ventilation mode IPPV,SIPPV,SIMV, MANUAL
■Ventilation function PEEP, SIGH, IRV
■Ventilation parameters Tidal volume 50~1500ml
Rate 2~99bmp
SIMV rate 2~20bpm
I:E 2:1~1:8
Inspiratory trigger pressure -10 ~20 cmH2O
PEEP 2~20 cmH2O
Pressure limitation 10~60 cmH2O
SIGH 1.5 times the inspiratory time
■Parameters for ventilation monitoring tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
■Security Alarm System
Airway pressure alarm upper limit setting range 5~60 cmH2O
low limit setting range 0~50 cmH2O
Minute ventilation volume alarm upper limit setting range 1~20 L/min
low limit setting range 0~19 L/min
Tidal volume upper limit setting range 100~1500ml
low limit setting range 0~1400ml
Sustained high-pressure alarm it will give alarm when stress have consistently
been higher than 2.5 cmH2O
(Suffocation alarm, Power alarm, Intubation off alarm, battery voltage alarm)
■Power AC 220V 50Hz (UPS, Storage battery)
■(Mechanical Arms) ■(End-tidal CO2 monitoring)
■(Specific interface of waste anesthesia gas)
*Items within brackets are optional.